| Permanent line – interactive
stabilisation
Controlled by microprocessor in
order to supply a stable tension to
the load by means of the AVR,
Booster and Fader Functions, which
imply an optimised use of batteries.
Should the allowed limits be
exceeded (+/-25%), the equipment
supplies tension through the batteries.
Communication Software
Win 95/98/NT and Novell Netware.
Display of the main parameters of
the equipment and organised closure
of files as back-up comes to
its end. Warning for configurable
alarms, current status chart, historical
record of events, weekly agenda
for turning off / starting, actual
time network analyser. |
 |
ColdStart: Start up without presence
of mains supply.
SleepMode: Disconnection due to
absence of load.
ABM-Advanced Battery Management:
battery charging sensitive to
variations temperature.
Protection of Fax facility/Modem
line.
Protecting device against overvoltages
and overloads on the fax/
modem/Internet line through port
RJ11.
Test of the equipment:
This can be also done anytime during
operation by using the keyboard, or
the software. Every time the equipment
is started up, it tests the batteries
and issues a warning signal in the
event it becomes necessary to replace
the batteries.
|
|
|
|
Technology:
|
Line-Interactive
|
| Input voltage:
|
172-287 Vac
|
| Stabilisation (AVR)
|
Booster / Fader
|
| Input frequency:
|
50 / 60 Hz +/-10% (auto-detection)
|
| Output voltage:
|
230 Vac +/-5% (on battery)
|
| Waveform
|
Stepwave (in battery)
|
| Output frequency:
|
50 / 60 Hz +/- 0,5% (on battery)
|
| Transfer time:
|
2/4 milliseconds
|
| Protections:
|
Against overload, short-circuit
|
| EMI/RFI Filter:
|
10 dB at 0,15 MHz, 50 dB at 30 MHz
|
| Advanced functions:
|
ColdStart / ABM / SleepMode
|
| Batteries
|
Pb-Ca, sealed, maintenance free
|
| Recharging time:
|
4 hours at 90% of charge
|
| Interface (*)
|
RS-232 (DB9, bi-directional)
|
| Communication software (*)
|
> Win 95/98/NT + Novell Netware
|
| Protector for phone/modem line (*)
|
2 x RJ11
|
| Battery protection
|
Automatic self-test, replacement warning
signal
|
| Safety standard
|
EN50091-1
|
| EMC Standard
|
EN50091-2
|
| Mark
|
EC
|
| Quality
|
ISO-9001
|
| (*): except for model SPS.325.PRO
|
|
|
|
| HEIGHT |
 |
POWER |
 |
SIZE (d x w x h, in mm.) |
 |
WEIGHT (VA/W) |
 |
|
|
| SPS.325.PRO |
325 / 195 |
274 x 96 x 137 |
4,7 kg |
| SPS.425.PRO |
425 / 255 |
327 x 96 x 137 |
5,6 kg |
| SPS.625.PRO |
625 / 375 |
327 x 96 x 137 |
6,2 kg |
| SPS.800.PRO |
800 / 480 |
393 x 130 x 200 |
12,5 kg |
| SPS.1000.PRO |
1000 / 600 |
393 x 130 x 200 |
13,4 kg |
| SPS.1000.PRO |
1000 / 600 |
393 x 130 x 200 |
13,4 kg |
| SPS.1200.PRO |
1200 / 720 |
393 x 130 x 200 |
15,2 kg |
|
|
|
|
Continuous sinewave supply
Continuous supply of output sinewave
voltage, both when operating
on stabiliser (Double Booster +
Fader) and with batteries. The best
quality output voltage is provided
and is furthermore compatible with
all of the critical loads that need to
be protected.
Complete Indications
A complete synoptic chart allows a
fast and easy understanding of the
current status of the equipment.
These are the indications displayed:
Operation on network or batteries.
Stabiliser mode in case of overvoltage
(Fader) or voltage drop (Double
Booster).
Overload indicator and warning to
replace batteries.
Leds bar for battery status.
Leds bar for connected load. |
 |
Added features and performance
qualities as standard that contribute
to provide an improved protection
for connected loads:
HotSwap:
Batteries can be replaced
by the user himself.
ColdStart:
Starting up without help
from mains supply.
SleepMode:
Disconnection when
there is no load connected.
ABM-Advanced Battery Management:
Batteries are charged in
terms of temperature.
Versions on 19" rack
Available in four different power
rates (800, 1250,1500 and 2000 VA)
for networks and telecommunications
applications.
Communication Software
By default in all models intended
for monitoring the equipment via
PC, along with the following functions:
start/stop, mains failure warning
signal and subsequent closing
of files.
|
|
|
|
Technology:
|
Line-Interactive
|
| Input voltage:
|
172-287 Vac
|
| Stabilisation (AVR)
|
Double Booster / Fader
|
| Input frequency:
|
50 / 60 Hz +/-10% (auto-detection)
|
| Output voltage:
|
230 Vac +/-3% (in battery)
|
| Waveform
|
Sinewave
|
| Output frequency:
|
50 / 60 Hz +/- 0,5% (in battery)
|
| Transfer time:
|
2/4 milliseconds
|
| Protections:
|
Overload, short-circuit
|
| EMI/RFI Filter:
|
10 dB a 0,15 MHz, 50 dB a 30 MHz
|
| Advanced functions:
|
ColdStart / ABM / SleepMode / HotSwap
|
| Batteries
|
Pb-Ca, sealed, maintenance free
|
| Recharging time:
|
4 hours at 90% of charge
|
| Interface (*)
|
RS-232 (DB9, bi-directional)
|
| Communication software (*)
|
> Win 95/98/NT + Novell Netware
|
| Protector for phone/modem line (*)
|
2 x RJ11
|
| Battery protection
|
Automatic self-test, replacement warning
/ indicator
|
| Safety standard
|
EN50091-1
|
| EMC Standard
|
EN50091-2
|
| Mark
|
EC
|
| Quality
|
ISO-9001
|
|
|
|
| HEIGHT |
 |
POWER |
 |
SIZE (d x w x h, in mm.) |
 |
WEIGHT (VA/W) |
 |
|
|
| SPS.400.TOP |
400/ 240 |
435 x 140 x 208 |
13 kg |
| SPS.600.TOP |
600 / 360 |
435 x 140 x 208 |
13,4 kg |
| SPS.800.TOP |
800 / 480 |
435 x 140 x 208 |
14,2 kg |
| SPS.1000.TOP |
1000 / 600 |
435 x 140 x 208 |
15 kg |
| SPS.1250.TOP |
1250 / 750 |
435 x 140 x 208 |
18 kg |
| SPS.1500.TOP |
1500 / 900 |
440 x 170 x 225 |
22,2 kg |
| SSPS.2000.TOP |
1200 / 720 |
440 x 170 x 225 |
26,9 kg |
| SSPS.2500.TOP |
1200 / 720 |
440 x 170 x 225 |
30 kg |
| Models available on 19" rack
|
| SPS.800.TOP R |
 |
800 / 480 |
 |
388 x 483 x 130 (3U) |
 |
19 kg |
 |
| SPS.1250.TOP R |
1250 / 750 |
388 x 483 x 130 (3U) |
23,5 kg |
| SPS.800.TOP R |
1500 / 900 |
388 x 483 x 130 (3U) |
26,1 kg |
| SPS.800.TOP R |
2000 / 1200 |
388 x 483 x 130 (3U) |
28,4 kg |
|
|
|